' ///////////////////////////////////////////////////////////////////////////
' // Description: Data Access class for the table 'mehrfachscann'
' // Generated by LLBLGen v1.2.1045.38210 Final on: Mittwoch, 19. Juli 2006, 15:16:33
' // Because the Base Class already implements IDispose, this class doesn't.
' ///////////////////////////////////////////////////////////////////////////
Imports System
Imports System.Data
Imports System.Data.SqlTypes
Imports System.Data.SqlClient
Namespace edokadb
' ///
' /// Purpose: Data Access class for the table 'mehrfachscann'.
' ///
Public Class clsMehrfachscann
Inherits clsDBInteractionBase
#Region " Class Member Declarations "
Private m_bAktiv As SqlBoolean
Private m_daStatusdatum, m_daMutiert_am, m_daErstellt_am, m_daMutationsdatum As SqlDateTime
Private m_iMutierer, m_iNreintrag, m_iStatus, m_iMandantnr As SqlInt32
Private m_sDokumentid, m_sStapelnr, m_sColddokumentid As SqlString
#End Region
' ///
' /// Purpose: Class constructor.
' ///
Public Sub New()
' // Nothing for now.
End Sub
' ///
' /// Purpose: Insert method. This method will insert one new row into the database.
' ///
' /// True if succeeded, otherwise an Exception is thrown.
' ///
' /// Properties needed for this method:
' ///
' /// - iNreintrag
' /// - daMutationsdatum
' /// - sColddokumentid. May be SqlString.Null
' /// - sStapelnr
' /// - iStatus
' /// - daStatusdatum
' /// - iMandantnr. May be SqlInt32.Null
' /// - bAktiv. May be SqlBoolean.Null
' /// - daErstellt_am. May be SqlDateTime.Null
' /// - daMutiert_am. May be SqlDateTime.Null
' /// - iMutierer. May be SqlInt32.Null
' /// - sDokumentid. May be SqlString.Null
' ///
' /// Properties set after a succesful call of this method:
' ///
' ///
Overrides Public Function Insert() As Boolean
Dim scmCmdToExecute As SqlCommand = New SqlCommand()
'scmCmdToExecute.CommandText = "dbo.[pv_mehrfachscann_Insert]"
scmCmdToExecute.CommandText = "dbo.[pv_mehrfachscann_Insert_EDKB02]"
scmCmdToExecute.CommandType = CommandType.StoredProcedure
' // Use base class' connection object
scmCmdToExecute.Connection = m_scoMainConnection
Try
scmCmdToExecute.Parameters.Add(New SqlParameter("@inreintrag", SqlDbType.Int, 4, ParameterDirection.Input, False, 10, 0, "", DataRowVersion.Proposed, m_iNreintrag))
scmCmdToExecute.Parameters.Add(New SqlParameter("@damutationsdatum", SqlDbType.DateTime, 8, ParameterDirection.Input, False, 23, 3, "", DataRowVersion.Proposed, m_daMutationsdatum))
scmCmdToExecute.Parameters.Add(New SqlParameter("@scolddokumentid", SqlDbType.VarChar, 255, ParameterDirection.Input, True, 0, 0, "", DataRowVersion.Proposed, m_sColddokumentid))
scmCmdToExecute.Parameters.Add(New SqlParameter("@sstapelnr", SqlDbType.VarChar, 20, ParameterDirection.Input, False, 0, 0, "", DataRowVersion.Proposed, m_sStapelnr))
scmCmdToExecute.Parameters.Add(New SqlParameter("@istatus", SqlDbType.Int, 4, ParameterDirection.Input, False, 10, 0, "", DataRowVersion.Proposed, m_iStatus))
scmCmdToExecute.Parameters.Add(New SqlParameter("@dastatusdatum", SqlDbType.DateTime, 8, ParameterDirection.Input, False, 23, 3, "", DataRowVersion.Proposed, m_daStatusdatum))
scmCmdToExecute.Parameters.Add(New SqlParameter("@imandantnr", SqlDbType.Int, 4, ParameterDirection.Input, True, 10, 0, "", DataRowVersion.Proposed, m_iMandantnr))
scmCmdToExecute.Parameters.Add(New SqlParameter("@baktiv", SqlDbType.Bit, 1, ParameterDirection.Input, True, 1, 0, "", DataRowVersion.Proposed, m_bAktiv))
scmCmdToExecute.Parameters.Add(New SqlParameter("@daerstellt_am", SqlDbType.DateTime, 8, ParameterDirection.Input, True, 23, 3, "", DataRowVersion.Proposed, m_daErstellt_am))
scmCmdToExecute.Parameters.Add(New SqlParameter("@damutiert_am", SqlDbType.DateTime, 8, ParameterDirection.Input, True, 23, 3, "", DataRowVersion.Proposed, m_daMutiert_am))
scmCmdToExecute.Parameters.Add(New SqlParameter("@imutierer", SqlDbType.Int, 4, ParameterDirection.Input, True, 10, 0, "", DataRowVersion.Proposed, m_iMutierer))
scmCmdToExecute.Parameters.Add(New SqlParameter("@sdokumentid", SqlDbType.VarChar, 22, ParameterDirection.Input, True, 0, 0, "", DataRowVersion.Proposed, m_sDokumentid))
scmCmdToExecute.Parameters.Add(new SqlParameter("@iErrorCode", SqlDbType.Int, 4, ParameterDirection.Output, True, 10, 0, "", DataRowVersion.Proposed, m_iErrorCode))
If m_bMainConnectionIsCreatedLocal Then
' // Open connection.
m_scoMainConnection.Open()
Else
If m_cpMainConnectionProvider.bIsTransactionPending Then
scmCmdToExecute.Transaction = m_cpMainConnectionProvider.stCurrentTransaction
End If
End If
' // Execute query.
scmCmdToExecute.ExecuteNonQuery()
m_iErrorCode = scmCmdToExecute.Parameters.Item("@iErrorCode").Value
If Not m_iErrorCode.Equals(New SqlInt32(LLBLError.AllOk)) Then
' // Throw error.
Throw New Exception("Stored Procedure 'pv_mehrfachscann_Insert' reported the ErrorCode: " & m_iErrorCode.ToString())
End If
Return True
Catch ex As Exception
' // some error occured. Bubble it to caller and encapsulate Exception object
Throw New Exception("clsMehrfachscann::Insert::Error occured.", ex)
Finally
If m_bMainConnectionIsCreatedLocal Then
' // Close connection.
m_scoMainConnection.Close()
End If
scmCmdToExecute.Dispose()
End Try
End Function
#Region " Class Property Declarations "
Public Property [iNreintrag]() As SqlInt32
Get
Return m_iNreintrag
End Get
Set(ByVal Value As SqlInt32)
Dim iNreintragTmp As SqlInt32 = Value
If iNreintragTmp.IsNull Then
Throw New ArgumentOutOfRangeException("iNreintrag", "iNreintrag can't be NULL")
End If
m_iNreintrag = Value
End Set
End Property
Public Property [daMutationsdatum]() As SqlDateTime
Get
Return m_daMutationsdatum
End Get
Set(ByVal Value As SqlDateTime)
Dim daMutationsdatumTmp As SqlDateTime = Value
If daMutationsdatumTmp.IsNull Then
Throw New ArgumentOutOfRangeException("daMutationsdatum", "daMutationsdatum can't be NULL")
End If
m_daMutationsdatum = Value
End Set
End Property
Public Property [sColddokumentid]() As SqlString
Get
Return m_sColddokumentid
End Get
Set(ByVal Value As SqlString)
m_sColddokumentid = Value
End Set
End Property
Public Property [sStapelnr]() As SqlString
Get
Return m_sStapelnr
End Get
Set(ByVal Value As SqlString)
Dim sStapelnrTmp As SqlString = Value
If sStapelnrTmp.IsNull Then
Throw New ArgumentOutOfRangeException("sStapelnr", "sStapelnr can't be NULL")
End If
m_sStapelnr = Value
End Set
End Property
Public Property [iStatus]() As SqlInt32
Get
Return m_iStatus
End Get
Set(ByVal Value As SqlInt32)
Dim iStatusTmp As SqlInt32 = Value
If iStatusTmp.IsNull Then
Throw New ArgumentOutOfRangeException("iStatus", "iStatus can't be NULL")
End If
m_iStatus = Value
End Set
End Property
Public Property [daStatusdatum]() As SqlDateTime
Get
Return m_daStatusdatum
End Get
Set(ByVal Value As SqlDateTime)
Dim daStatusdatumTmp As SqlDateTime = Value
If daStatusdatumTmp.IsNull Then
Throw New ArgumentOutOfRangeException("daStatusdatum", "daStatusdatum can't be NULL")
End If
m_daStatusdatum = Value
End Set
End Property
Public Property [iMandantnr]() As SqlInt32
Get
Return m_iMandantnr
End Get
Set(ByVal Value As SqlInt32)
m_iMandantnr = Value
End Set
End Property
Public Property [bAktiv]() As SqlBoolean
Get
Return m_bAktiv
End Get
Set(ByVal Value As SqlBoolean)
m_bAktiv = Value
End Set
End Property
Public Property [daErstellt_am]() As SqlDateTime
Get
Return m_daErstellt_am
End Get
Set(ByVal Value As SqlDateTime)
m_daErstellt_am = Value
End Set
End Property
Public Property [daMutiert_am]() As SqlDateTime
Get
Return m_daMutiert_am
End Get
Set(ByVal Value As SqlDateTime)
m_daMutiert_am = Value
End Set
End Property
Public Property [iMutierer]() As SqlInt32
Get
Return m_iMutierer
End Get
Set(ByVal Value As SqlInt32)
m_iMutierer = Value
End Set
End Property
Public Property [sDokumentid]() As SqlString
Get
Return m_sDokumentid
End Get
Set(ByVal Value As SqlString)
m_sDokumentid = Value
End Set
End Property
#End Region
End Class
End Namespace